- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- Definitions of Managed Objects
- for Frame Relay Service
- draft-ieft-frnetmib-fr-04.txt
-
- October 14, 1993
-
- Frame Relay Service MIB Working Group
-
- Tracy A. Brown (editor)
- Bell Communications Research
- 331 Newman Springs Road
- Red Bank, NJ 07701
-
- tacox@mail.bellcore.com
-
-
-
- 1. Status of this Memo
-
- This document is an Internet Draft. Internet Drafts are
- working documents of the Internet Engineering Task Force
- (IETF), its Areas, and its Working Groups. Note that other
- groups may also distribute working documents as Internet
- Drafts.
-
- Internet Drafts are draft documents valid for a maximum of six
- months. Internet Drafts may be updated, replaced, or obsoleted
- by other documents at any time. It is not appropriate to use
- Internet Drafts as reference material or to cite them other
- than as a "working draft" or "work in progress."
-
- Please check the I-D abstract listing contained in each
- Internet Draft directory to learn the current status of this
- or any other Internet Draft.
-
- 2. Abstract
-
- This memo defines an extension to the Management Information
- Base (MIB) for use with network management protocols in
- TCP/IP-based internets. In particular, it defines objects for
- managing the Frame Relay Service.
-
- This memo does not specify a standard for the Internet
- community.
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 1]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- 3. The SNMPv2 Network Management Framework
-
- The SNMPv2 Network Management Framework consists of four major
- components. They are:
-
- o RFC 1442 which defines the SMI, the mechanisms used for
- describing and naming objects for the purpose of
- management.
-
- o RFC 1213 defines MIB-II, the core set of managed objects
- for the Internet suite of protocols.
-
- o RFC 1445 which defines the administrative and other
- architectural aspects of the framework.
-
- o RFC 1448 which defines the protocol used for network
- access to managed objects.
-
- The Framework permits new objects to be defined for the
- purpose of experimentation and evaluation.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 2]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- 4. Object Definitions
- Managed objects are accessed via a virtual information store,
- termed the Management Information Base or MIB. Objects in the
- MIB are defined using the subset of Abstract Syntax Notation
- One (ASN.1) defined in the SMI. In particular, each object
- object type is named by an OBJECT IDENTIFIER, an
- administratively assigned name. The object type together with
- an object instance serves to uniquely identify a specific
- instantiation of the object. For human convenience, we often
- use a textual string, termed the descriptor, to refer to the
- object type.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 3]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- 5. Overview
-
- These objects are used when the particular media being used to
- manage is Frame Relay Service. At present, this applies to
- these values of the ifType variable in the Internet-standard
- MIB:
-
- frameRelayService (44)
-
- This section provides an overview and background of how to use
- this MIB and other potential MIBs when managing a Frame Relay
- Service.
-
- Figure 1 shows the MIB stack that could be followed for
- managing a Frame Relay Service. This is only an example and
- not meant to be inclusive.
- ____________________________________________________
- | | | | |
- | | | SIP | RFC1490 |
- | | X.25 MIB | Relay | (no applic.|
- | | for IW/Encap.| MIB | MIB) |
- | | | | |
- | MIB II |-----------------------------------|
- | | |
- | ifTable | Frame Relay Service MIB |
- | ifStackTable |___________________________________|
- | | | |
- | | Physical Layer MIBs | ATM MIB |
- | | e.g., DS1/E1 MIB, |---------|
- | | RS232-like MIB | Phy. |
- | | | Layer |
- | | | MIB |
- |--------------|-------------------------|---------|
-
-
- Figure 1. Frame Relay MIB Architecture
-
-
-
- 5.1. Scope of MIB
-
- The Frame Relay Service MIB will only manage the Frame Relay
- portion of the network. This MIB is based upon the Customer
- Network Management concepts presented in the document "Service
- Management Architecture for Virtual Connection Services" [6].
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 4]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- This MIB will NOT be implemented on User Equipment (e.g.,
- DTE), and the Frame Relay DTE MIB (RFC1315) should be used to
- manage those devices.
-
- Frame Relay Service MIB is intended to be used for Customer
- Network Management (CNM) of a Frame Relay Network Service. It
- provides information that allows end-customers to obtain
- performance monitoring, fault detection, and configuration
- information about their Frame Relay Service.
-
- By using this and other related MIBs, a customer's NMS can
- monitor their PVCs and UNI/NNI logical ports. Internal
- aspects of the network (e.g., switching elements, line cards,
- and network routing tables) are outside the scope of this MIB.
- The Customer's NMS will typically access the SNMP proxy-agent
- within the Frame Relay network using SNMP over UDP over IP
- with IP encapsulated in Frame Relay according to RFC1490/ANSI
- T1.617 Annex F. The customer, thus, has a PVC to the SNMP
- proxy-agent. Alternate access mechanisms and SNMP agent
- implementations are possible. The service capabilities
- include retrieving information and receiving TRAPs. It is
- beyond the scope of this MIB to define managed objects to
- monitor the physical layer. Existing physical layer MIBs
- (e.g., DS1 MIB) and MIB II will be used as possible. The
- Frame Relay Service SNMP MIB for CNM will not contain any
- managed objects to monitor the physical layer. This MIB
- primarily addresses Frame Relay PVCs. This MIB may be
- extended at a later time to handle Frame Relay SVCs.
-
- This MIB is only used to manage a single Frame Relay Service
- offering from one network. This MIB will typically be
- implemented on a service provider's SNMP proxy-agent. The SNMP
- proxy-agent proxies for all Frame Relay equipment within one
- service provider's Frame Relay network. (Other SNMP agent
- implementations are not precluded.) Therefore, this MIB models
- a PVC segment through one Frame Relay Network. See Figure 2.
- If the customer's PVCs traverse multiple networks, then the
- customer needs to poll multiple network proxy-agents within
- each Frame Relay Network to retrieve their end-to-end view of
- their service. See Figure 2 and the Service Management
- Architecture [6].
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 5]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- +-------------------------------------+
- | Customer Network Management Station |
- | (SNMP based) |
- +-------------------------------------+
- ^ ^ ^
- | | |
- | | |
- UNI | NNI | NNI | UNI
- | ^ | ^ | ^
- | +-----------+ | +-----------+ | +-----------+ |
- | | | | | | | | | |
- Originating | | FR | | | FR | | | FR | |Terminating
- +--------+ | | Network I | | | Network J | | | Network K | | +--------+
- | | | | | | | | | | | | | |
- | |----| |---| |---| |----| User B |
- | | | | | | | | | | | | | |
- | ////////////////////////////////////////////////////////////// |
- | | | | | | | | | | | | | |
- +--------+ | +-----------+ | +-----------+ | +-----------+ | +--------+
- | | | |
- | | | |
- | PVC Segment 1 | PVC Segment 2 | PVC Segment 3 |
- |<------------->|<------------->|<------------->|
- | |
- | Multi-network PVC |
- |<--------------------------------------------->|
- | NNI = Network-to Network Interface |
- UNI = User-to-Network Interface
-
- Figure 2. Multi-network PVC
-
-
- Also, since the Frame Relay network is a shared network
- amongst many Frame Relay subscribers, each subscriber will
- only have access to their information (e.g., information with
- respect to their interfaces and PVCs). Therefore, in order to
- provide this capability, the Frame Relay PVC CNM proxy agent
- should be able to support instance level granularity for MIB
- views. See the Service Management Architecture.
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 6]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- 5.2. Frame Relay Service MIB Terminology
-
- Access Channel - An access channel generically refers to the
- DS1/E1 or DS3/E3-based UNI access channel or NNI access
- channel across which frame relay data transits. An access
- channel is the access pathway for a single stream of user
- data.
-
- Within a given T1 line, an access channel can denote any one
- of the following:
-
- o Unchannelized T1 - the entire T1 line is considered an access
- channel. Each access channel is comprised of 24 T1 time slots.
-
- o Channelized T1 - an access channel is any one of 24 channels.
- Each access channel is comprised of a single T1 time slot.
-
- o Fractional T1 - an access channel is a grouping of N T1 time
- slots (NX56/64 Kbps, where N = 1-23 T1 Time slots per FT1 Access
- Channel) that may be assigned in consecutive or non-consecutive
- order.
-
- Within a given E1 line, a channel can denote any one of the following:
-
- o Unchannelized E1 - the entire E1 line is considered a single
- access channel. Each access channel is comprised of 31 E1 time
- slots.
-
- o Channelized E1 - an access channel is any one of 31 channels.
- Each access channel is comprised of a single E1 time slot.
-
- o Fractional E1 - an access channel is a grouping of N E1 time
- slots (NX64 Kbps, where N = 1-30 E1 time slots per FE1 access
- channel) that may be assigned in consecutive or non-consecutive
- order.
-
- Within a given unformatted line, the entire unformatted line
- is considered an access channel. Examples include RS-232,
- V.35, V.36 and X.21 (non- switched).
-
- Access Rate - The data rate (expressed in bits/s) of the user
- access channel. The speed of the access channel determines
- how much data (maximum rate) the end user can inject into the
- network.
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 7]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- Bc - The Committed Burst Size (Bc) is the maximum committed
- amount of data (expressed in bits) a user may offer to the
- network during a time interval Tc. Bc is negotiated at call
- set-up.
-
- Be - The Excess Burst Size (Be) is the maximum allowed amount
- of data (expressed in bits) by which a user can exceed Bc
- during a time interval Tc. This data (Be) is delivered in
- general with a lower probability than Bc. Be is negotiated at
- call set-up.
-
- CIR - The Committed Information Rate (CR) is the information
- transfer rate (expressed in bits/s) at which the network is
- committed to transfer information under normal conditions.
- The rate is averaged over a minimum increment of time Tc. CIR
- is negotiated at call set-up.
-
- DLCI - Data Link Connection Identifier
-
- Logical Port - This term is used to model the Frame Relay
- "interface" on a device.
-
- NNI - Network to Network Interface
-
- Permanent Virtual Connection (PVC) - A virtual connection that
- has its end-points and bearer capabilities defined at
- subscription time.
-
- Time slot (E1) - An octet within the 256-bit information field
- in each E1 frame is defined as a time slot. Time slots are
- position sensitive within the 256-bit information field.
- Fractional E1 service is provided in contiguous or non-
- contiguous time slot increments.
-
- Time slot (T1) - An octet within the 192-bit information field
- in each T1 frame is defined as a time slot. Time slots are
- position sensitive within the 192-bit information field.
- Fractional T1 service is provided in contiguous or non-
- contiguous time slot increments.
-
- UNI - User to Network Interface
-
- N391 - Full status (status of all PVCs) polling counter
-
- N392 - Error threshold
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 8]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- N393 - Monitored events count
-
- T391 - Link integrity verification polling timer
-
- T392 - Polling verification timer
-
- nT3 - Status enquiry timer
-
- nN3 - Maximum status enquiry counter
-
- 5.3. Apply MIB II to a Frame Relay Service
-
- Use the System Group to apply to the SNMP proxy-agent, since
- the proxy-agent may be monitoring many Frame Relay devices in
- one network. System Group applies to only one system. This
- group is not instantiated.
-
- sysDescr: ASCII string describing the SNMP proxy-agent.
- Can be up to 255 characters long. This field is
- generally used to indicate the network providers
- identification and type of service offered.
-
- sysObjectID: Unique OBJECT IDENTIFIER (OID) for the SNMP
- proxy-agent.
-
- sysUpTime: Clock in the SNMP proxy-agent; TimeTicks
- in 1/100s of a second. Elapsed type since
- the proxy-agent came on line.
-
- sysContact: Contact for the SNMP proxy-agent.
- ASCII string of up to 255 characters.
-
- sysName: Domain name of the SNMP proxy-agent, for example,
- acme.com
-
- sysLocation: Location of the SNMP proxy-agent.
- ASCII string of up to 255 characters.
-
- sysServices: Services of the managed device. The value "2"
- which implies that
- the Frame Relay network is providing
- a subnetwork level service is recommended.
-
- This specifies how the Interfaces Group defined in MIB II
- shall be used for the management of Frame Relay based
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 9]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- interfaces, and in conjunction with the Frame Relay Service
- MIB module. This memo assumes the interpretation of the
- evolution of the Interfaces group to be in accordance with:
- "The interfaces table (ifTable) contains information on the
- managed resource's interfaces. Each sub- layer below the
- internetwork layer of a network interface is considered an
- interface." Thus, the ifTable allows the following Frame
- Relay-based interfaces to be represented as table entries:
-
- - Frame Relay interfaces in the Frame Relay equipment (e.g.,
- switches, routers or networks) with Frame Relay interfaces.
- This level is concerned with generic frame counts and
- not with individual virtual connections.
-
- In accordance with the guidelines of ifTable, frame counts per
- virtual connection are not covered by ifTable, and are
- considered interface specific and covered in the Frame Relay
- Service MIB module. In order to interrelate the ifEntries
- properly, the Interfaces Stack Group shall be supported.
-
- Some specific interpretations of ifTable for Frame Relay
- follow.
-
- Object Use for the generic Frame Relay layer
- ====== =========================================
- ifIndex Each Frame Relay port is represented by an ifEntry.
-
- ifDescr Description of the Frame Relay interface.
- ASCII string describing the UNI/NNI logical port.
- Can be up to
- 255 characters long.
-
- ifType The value allocated for Frame Relay Service
- is equal to 44.
-
- ifMtu Set to maximum frame size in octets for this
- frame relay
- logical port.
-
- ifSpeed Peak bandwidth in bits per second available for use.
- This could be the speed of the logical port and not
- the access rate. Actual user information transfer
- rate (i.e., access rate) of the
- UNI or NNI logical
- port in bits per second (this is not the clocking
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 10]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- speed). For example, it is 1,536,000 bits per
- second for a DS1-based UNI/NNI logical port
- and 1,984,000 bits per second for an E1-based UNI/NNI
- logical port.
-
- ifPhysAddress The primary address for this logical port
- assigned by the Frame Relay interface provider.
- An octet string of zero length if no address is
- used for this logical port.
-
- ifAdminStatus Supports read-only access (initially).
- The desired administrative status of the frame relay
- logical port.
-
- ifOperStatus The current operational status of the Frame Relay
- UNI or NNI logical port.
-
- ifLastChange The elapsed time since the last re-initialization of
- the logical port.
- The value of sysUpTime at the time the
- logical port entered
- its current operational state. If the current state
- was entered prior to
- the last re-initialization of the local network
- management subsystem, then
- this object contains a zero value.
-
- ifInOctets The number of received octets.
- This counter only counts octets from the
- beginning of the frame relay header field to
- the end of user data.
-
- ifInUcastPkts The number of received unerrored,
- unicast frames.
-
- ifInDiscards The number of received frames discarded. Possible
- reasons are as follows: policing,
- congestion.
-
- ifInErrors The number of received frames that are
- discarded, because of an error.
- Possible errors can be
- the following: the frame relay frames
- were too long or were too short, the frames
- had an invalid or unrecognized DLCI values,
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 11]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- or incorrect header values.
-
- ifInUnknownProtos noSuchName
-
- ifOutOctets The number of transmitted octets.
- This counter only counts octets from the
- beginning of the frame relay header field to
- the end of user data.
-
- ifOutUcastpkts The number of frames sent.
- [Ed. note: Frame Relay switches provide counts of
- transmitted frames and not of frames received
- for transmission as required by the ifTable.
- This is because the latter counter is
- switch architecture dependent.
- Comments are requested on this issue.]
-
- ifOutDiscards The number of frames discarded in the
- egress direction. Possible
- reasons are as follows: policing,
- congestion.
-
- ifOutErrors The number of frames discarded in the egress
- direction, because of errors.
- Possible reason is transmit underruns.
-
- ifSpecific Set to the OBJECT IDENTIFIER for
- frLportNumPlan.frLportIfIndex for this ifEntry.
-
- ifName noSuchName
-
- ifInMulticastPkts The number of received unerrored,
- multicast frames.
-
- ifInBroadcastPkts noSuchName
-
- ifOutMulticastPkts The number of sent unerrored,
- multicast frames.
-
- ifOutBroadcastPkts noSuchName
-
- ifHCInOctets Only used for DS3-based (and greater) Frame
- Relay logical ports.
- The number of received octets.
- This counter only counts octets from the
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 12]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- beginning of the frame relay header field to
- the end of user data.
-
- ifHCOutOctets Only used for DS3-based (and greater) Frame
- Relay logical ports.
- The number of transmitted octets.
- This counter only counts octets from the
- beginning of the frame relay header field to
- the end of user data.
-
- ifLinkUpDownTrapEnble The value of this object is
- implementation specific for Frame Relay
- logical ports.
-
- ifHighSpeed Set to the user data rate of the frame
- relay logical port in millions of
- bits per second. If the user data rate
- is less than 1 Mbps, then this value is zero.
-
- ifPromiscuousMode Set to false(2).
-
-
-
- Frame Relay Network Service interfaces do not support any
- other groups or objects in the Interfaces group of MIB II.
- Also, using the SNMP Group of MIB II is an implementation
- choice.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 13]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- 6. Object Definitions
-
- FRNETSERV-MIB DEFINITIONS ::= BEGIN
-
- IMPORTS
- MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
- Counter32, Integer32,
- TimeTicks, experimental FROM SNMPv2-SMI
- DisplayString, PhysAddress, RowStatus FROM SNMPv2-TC
- MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF;
-
-
- frnetservMIB MODULE-IDENTITY
- LAST-UPDATED "9310141200Z"
- ORGANIZATION "IETF Frame Relay Network MIB Working Group"
- CONTACT-INFO
- " Tracy A. Brown
- Bellcore
- 331 Newman Springs Rd.
- Red Bank, NJ 07701 USA
-
- Tel: 1-908-758-2107
- Fax: 1-908-758-4177
- E-mail: tacox@mail.bellcore.com."
- DESCRIPTION
- "The MIB module to describe generic objects for
- Frame Relay Network Service."
- ::= { experimental 45 }
-
- frnetservObjects OBJECT IDENTIFIER ::= { frnetservMIB 1 }
- frnetservTraps OBJECT IDENTIFIER ::= { frnetservMIB 2 }
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 14]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- -- The Frame Relay Service Logical Port Group
-
- -- the Frame Relay Logical Port Group
- -- This table is an interface specific addendum
- -- to the generic ifTable from MIB-II.
-
- frLportTable OBJECT-TYPE
- SYNTAX SEQUENCE OF FrLportEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The Frame Relay Logical Port Information table."
- ::= { frnetservObjects 1 }
-
- frLportEntry OBJECT-TYPE
- SYNTAX FrLportEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "An entry in the Frame Relay Logical Port
- Information table."
- INDEX { frLportIfIndex }
- ::= { frLportTable 1 }
-
- FrLportEntry ::=
- SEQUENCE {
- frLportIfIndex
- Integer32,
- frLportNumPlan
- INTEGER,
- frLportContact
- DisplayString,
- frLportLocation
- DisplayString,
- frLportType
- INTEGER,
- frLportAddrDLCILen
- INTEGER,
- frLportVCSigProtocol
- INTEGER,
- frLportVCSigPointer
- OBJECT IDENTIFIER
- }
-
- frLportIfIndex OBJECT-TYPE
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 15]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- SYNTAX Integer32
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The value of this object is equal to MIB II's
- ifIndex value for this UNI/NNI logical port."
- ::= { frLportEntry 1 }
-
- frLportNumPlan OBJECT-TYPE
- SYNTAX INTEGER {
- other(1),
- e164(2),
- x121(3),
- none(4)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the network
- address numbering plan for this UNI/NNI logical
- port. The network address is the object
- ifPhysAddress. The value none implies that there
- is no ifPhysAddress. The SNMP proxy-agent will
- return an octet string of zero length for
- ifPhysAddress. The value other means that an
- address has been assigned to this interface, but
- the numbering plan is not enumerated here."
- ::= { frLportEntry 2 }
-
- frLportContact OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..255))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the network
- contact for this UNI/NNI logical port."
- ::= { frLportEntry 3 }
-
- frLportLocation OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..255))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the Frame
- Relay network location for this UNI/NNI logical
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 16]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- port."
- ::= { frLportEntry 4 }
-
- frLportType OBJECT-TYPE
- SYNTAX INTEGER {
- uni(1),
- nni(2)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the type of
- network interface for this logical port."
- ::= { frLportEntry 5 }
-
- frLportAddrDLCILen OBJECT-TYPE
- SYNTAX INTEGER {
- twoOctets10Bits(1),
- threeOctets10Bits(2),
- threeOctets16Bits(3),
- fourOctets17Bits(4),
- fourOctets23Bits(5)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the Q.922
- Address field length and DLCI length for this
- UNI/NNI logical port."
- ::= { frLportEntry 6 }
-
- frLportVCSigProtocol OBJECT-TYPE
- SYNTAX INTEGER {
- none(1),
- lmi(2),
- ansiT1617D(3),
- ansiT1617B(4),
- ccittQ933A(5)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the Local
- In-Channel Signaling Protocol that is used for
- this frame relay UNI/NNI logical port."
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 17]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- ::= { frLportEntry 7 }
-
- frLportVCSigPointer OBJECT-TYPE
- SYNTAX OBJECT IDENTIFIER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object is used as a pointer to
- the table that contains the Local In-Channel
- Signaling Protocol parameters and errors for this
- UNI/NNI logical port. See the Frame Relay
- Management VC Signaling Parameters and Errors
- Group."
- ::= { frLportEntry 8 }
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 18]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- -- the Frame Relay Management VC Signaling Group
-
- -- This Group contains managed objects for the
- -- Local In-Channel Signaling Parameters and
- -- for signaling errors.
-
- frMgtVCSigTable OBJECT-TYPE
- SYNTAX SEQUENCE OF FrMgtVCSigEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The Frame Relay Management VC Signaling
- Parameters and Errors table."
- ::= { frnetservObjects 2 }
-
- frMgtVCSigEntry OBJECT-TYPE
- SYNTAX FrMgtVCSigEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "An entry in the Frame Relay Management VC
- Signaling Parameters Errors table."
- INDEX { frMgtVCSigIfIndex }
- ::= { frMgtVCSigTable 1 }
-
- FrMgtVCSigEntry ::=
- SEQUENCE {
- frMgtVCSigIfIndex
- Integer32,
- frMgtVCSigProced
- INTEGER,
- frMgtVCSigUserN391
- INTEGER,
- frMgtVCSigUserN392
- INTEGER,
- frMgtVCSigUserN393
- INTEGER,
- frMgtVCSigUserT391
- INTEGER,
- frMgtVCSigNetN392
- INTEGER,
- frMgtVCSigNetN393
- INTEGER,
- frMgtVCSigNetT392
- INTEGER,
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 19]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- frMgtVCSigNetnN4
- INTEGER,
- frMgtVCSigNetnT3
- INTEGER,
- frMgtVCSigUserLinkRelErrors
- Counter32,
- frMgtVCSigUserProtErrors
- Counter32,
- frMgtVCSigUserChanInactive
- Counter32,
- frMgtVCSigNetLinkRelErrors
- Counter32,
- frMgtVCSigNetProtErrors
- Counter32,
- frMgtVCSigNetChanInactive
- Counter32
- }
-
- frMgtVCSigIfIndex OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The value of this object is equal to MIB II's
- ifIndex value for this UNI/NNI logical port."
- ::= { frMgtVCSigEntry 1 }
-
- frMgtVCSigProced OBJECT-TYPE
- SYNTAX INTEGER {
- u2nnet(1),
- bidirect(2)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the Local
- In-Channel Signaling Procedure that is used for
- this UNI/NNI logical port. The UNI/NNI logical
- port can be performing only user-to-network
- network-side procedures or bidirectional
- procedures."
- ::= { frMgtVCSigEntry 2 }
-
- frMgtVCSigUserN391 OBJECT-TYPE
- SYNTAX INTEGER (1..255)
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 20]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the User-side
- N391 full status polling cycle value for this
- UNI/NNI logical port. If the logical port is not
- performing user-side procedures, then this value
- is equal to noSuchName. This object applies to
- Q.933 Annex A and T1.617 Annex D."
- DEFVAL { 6 }
- ::= { frMgtVCSigEntry 3 }
-
- frMgtVCSigUserN392 OBJECT-TYPE
- SYNTAX INTEGER (1..10)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the User-side
- N392 error threshold value for this UNI/NNI
- logical port. If the logical port is not
- performing user-side procedures, then this value
- is equal to noSuchName. This object applies to
- Q.933 Annex A and T1.617 Annex D."
- DEFVAL { 3 }
- ::= { frMgtVCSigEntry 4 }
-
- frMgtVCSigUserN393 OBJECT-TYPE
- SYNTAX INTEGER (1..10)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the User-side
- N393 monitored events count value for this UNI/NNI
- logical port. If the logical port is not
- performing user-side procedures, then this value
- is equal to noSuchName. This object applies to
- Q.933 Annex A and T1.617 Annex D."
- DEFVAL { 4 }
- ::= { frMgtVCSigEntry 5 }
-
- frMgtVCSigUserT391 OBJECT-TYPE
- SYNTAX INTEGER (5..30)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 21]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- "The value of this object identifies the User-side
- T391 link integrity verification polling timer
- value for this UNI/NNI logical port. If the
- logical port is not performing user-side
- procedures, then this value is equal to
- noSuchName. This object applies to Q.933 Annex A
- and T1.617 Annex D."
- DEFVAL { 10 }
- ::= { frMgtVCSigEntry 6 }
-
- frMgtVCSigNetN392 OBJECT-TYPE
- SYNTAX INTEGER (1..10)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the Network-
- side N392 error threshold value (nN2 for LMI) for
- this UNI/NNI logical port. If the logical port is
- not performing network-side procedures, then this
- value is equal to noSuchName. This object applies
- to Q.933 Annex A, T1.617 Annex D and LMI."
- DEFVAL { 3 }
- ::= { frMgtVCSigEntry 7 }
-
- frMgtVCSigNetN393 OBJECT-TYPE
- SYNTAX INTEGER (1..10)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the Network-
- side N393 monitored events count value (nN3 for
- LMI) for this UNI/NNI logical port. If the
- logical port is not performing network-side
- procedures, then this value is equal to
- noSuchName. This object applies to Q.933 Annex A,
- T1.617 Annex D and LMI."
- DEFVAL { 4 }
- ::= { frMgtVCSigEntry 8 }
-
- frMgtVCSigNetT392 OBJECT-TYPE
- SYNTAX INTEGER (5..30)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the Network-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 22]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- side T392 polling verification timer value (nT2
- for LMI) for this UNI/NNI logical port. If the
- logical port is not performing network-side
- procedures, then this value is equal to
- noSuchName. This object applies to Q.933 Annex A,
- T1.617 Annex D and LMI."
- DEFVAL { 15 }
- ::= { frMgtVCSigEntry 9 }
-
- frMgtVCSigNetnN4 OBJECT-TYPE
- SYNTAX INTEGER (5..5)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the Network-
- side nN4 maximum status enquires received value
- for this UNI/NNI logical port. If the logical
- port is not performing network-side procedures or
- is not performing LMI procedures, then this value
- is equal to noSuchName. This object applies only
- to LMI and always has a value of 5."
- ::= { frMgtVCSigEntry 10 }
-
- frMgtVCSigNetnT3 OBJECT-TYPE
- SYNTAX INTEGER (5 | 10 | 15 | 20 | 25 | 30)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the Network-
- side nT3 timer (for nN4 status enquires received)
- value for this UNI/NNI logical port. If the
- logical port is not performing network-side
- procedures or is not performing LMI procedures,
- then this value is equal to noSuchName. This
- object applies only to LMI."
- DEFVAL { 20 }
- ::= { frMgtVCSigEntry 11 }
-
- frMgtVCSigUserLinkRelErrors OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of user-side local in-channel
- signaling link reliability errors (i.e., non-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 23]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- receipt of Status/Status Enquiry messages or
- invalid sequence numbers in a Link Integrity
- Verification Information Element) for this UNI/NNI
- logical port. If the logical port is not
- performing user-side procedures, then this value
- is equal to noSuchName."
- ::= { frMgtVCSigEntry 12 }
-
- frMgtVCSigUserProtErrors OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of user-side local in-channel
- signaling protocol errors (i.e., protocol
- discriminator, message type, call reference, and
- mandatory information element errors) for this
- UNI/NNI logical port. If the logical port is not
- performing user-side procedures, then this value
- is equal to noSuchName."
- ::= { frMgtVCSigEntry 13 }
-
- frMgtVCSigUserChanInactive OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of times the user-side channel was
- declared inactive (i.e., N392 errors in N393
- events) for this UNI/NNI logical port. If the
- logical port is not performing user-side
- procedures, then this value is equal to
- noSuchName."
- ::= { frMgtVCSigEntry 14 }
-
- frMgtVCSigNetLinkRelErrors OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of network-side local in-channel
- signaling link reliability errors (i.e., non-
- receipt of Status/Status Enquiry messages or
- invalid sequence numbers in a Link Integrity
- Verification Information Element) for this UNI/NNI
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 24]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- logical port. If the logical port is not
- performing network-side procedures, then this
- value is equal to noSuchName."
- ::= { frMgtVCSigEntry 15 }
-
- frMgtVCSigNetProtErrors OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of network-side local in-channel
- signaling protocol errors (i.e., protocol
- discriminator, message type, call reference, and
- mandatory information element errors) for this
- UNI/NNI logical port. If the logical port is not
- performing network-side procedures, then this
- value is equal to noSuchName."
- ::= { frMgtVCSigEntry 16 }
-
- frMgtVCSigNetChanInactive OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of times the network-side channel was
- declared inactive (i.e., N392 errors in N393
- events) for this UNI/NNI logical port. If the
- logical port is not performing network-side
- procedures, then this value is equal to
- noSuchName."
- ::= { frMgtVCSigEntry 17 }
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 25]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- -- The Frame Relay PVC Connection Group
-
- -- The Frame Relay PVC Connection Group
- -- models a bi-directional PVC flow
- -- as two uni-directional
- -- PVC flows.
-
- -- Frame Relay Network Frame Relay Network
- -- Ingress ____________________________________ Egress
- -- | |
- -- ______| >> uni-directional PVC flow >> |____________
- -- |___________________________________|
- --
- -- Frame Relay Network Frame Relay Network
- -- Egress ____________________________________ Ingress
- -- | |
- -- ______| << uni-directional PVC flow << |____________
- -- |___________________________________|
- --
-
- -- The two uni-directional PVC flows provide information
- -- in the ingress to egress direction.
- -- Ingress is defined as going into the Frame Relay Network,
- -- and egress is defined as going out of the Frame
- -- Relay Network.
- -- If the Frame Relay Connection table is used to model
- -- a unidirectional PVC, then there is only one entry in this
- -- table for this unidirectional PVC. Performing a GET-Request by
- -- indexing the table in the reverse direction
- -- will return a noSuchName.
-
- -- A PVC segment flow is a portion of a PVC
- -- that traverses one Frame Relay Network, and
- -- a PVC segment flow is identified
- -- by its two end-points (UNI/NNI logical port index
- -- value and DLCI index value)
- -- through one Frame Relay Network.
-
- frPVCConnectTable OBJECT-TYPE
- SYNTAX SEQUENCE OF FrPVCConnectEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The Frame Relay PVC Connect table. A bi-
- directional PVC flow is modeled as two entries in
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 26]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- this table. Each entry models a uni-directional
- PVC flow."
- ::= { frnetservObjects 3 }
-
- frPVCConnectEntry OBJECT-TYPE
- SYNTAX FrPVCConnectEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "An entry in the Frame Relay PVC Connect table.
- This entry is used to model a PVC segment flow in
- one direction."
- INDEX { frPVCConnectIngressIfIndex, frPVCConnectIngressDLCIIndex,
- frPVCConnectEgressIfIndex, frPVCConnectEgressDLCIIndex }
- ::= { frPVCConnectTable 1 }
-
- FrPVCConnectEntry ::=
- SEQUENCE {
- frPVCConnectIngressIfIndex
- Integer32,
- frPVCConnectIngressDLCIIndex
- Integer32,
- frPVCConnectEgressIfIndex
- Integer32,
- frPVCConnectEgressDLCIIndex
- Integer32,
- frPVCConnectAdminStatus
- INTEGER,
- frPVCConnectOperStatus
- INTEGER,
- frPVCConnectLastChange
- TimeTicks,
- frPVCConnectMaxFrameSize
- Integer32,
- frPVCConnectBc
- Integer32,
- frPVCConnectBe
- Integer32,
- frPVCConnectCIR
- Integer32,
- frPVCConnectGenericPointer
- OBJECT IDENTIFIER,
- frPVCConnectStatus
- RowStatus
- }
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 27]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- frPVCConnectIngressIfIndex OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The value of this object is equal to MIB II's
- ifIndex value for the ingress UNI/NNI logical port
- for this uni-directional PVC flow."
- ::= { frPVCConnectEntry 1 }
-
- frPVCConnectIngressDLCIIndex OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the ingress
- DLCI value for this uni-directional PVC flow."
- ::= { frPVCConnectEntry 2 }
-
- frPVCConnectEgressIfIndex OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The value of this object is equal to MIB II's
- ifIndex value for the egress UNI/NNI logical port
- for this uni-directional PVC flow. If the value
- is equal to zero, then the egress logical port is
- not a frame relay UNI/NNI logical port."
- ::= { frPVCConnectEntry 3 }
-
- frPVCConnectEgressDLCIIndex OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the egress
- DLCI value for this uni-directional PVC flow. If
- the value is equal to zero, then the egress end of
- the PVC flow is not a Frame Relay connection."
- ::= { frPVCConnectEntry 4 }
-
- frPVCConnectAdminStatus OBJECT-TYPE
- SYNTAX INTEGER {
- deleted(1),
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 28]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- active(2),
- inactive(3),
- testing(4)
- }
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The value of this object identifies the desired
- administrative status of this uni-directional PVC
- flow. This state is set by an administrative
- entity. This value affects the PVC status
- indicated across the ingress NNI/UNI of the uni-
- directional PVC flow."
- ::= { frPVCConnectEntry 5 }
-
- frPVCConnectOperStatus OBJECT-TYPE
- SYNTAX INTEGER {
- deleted(1),
- active(2),
- inactive(3),
- testing(4),
- unknown(5)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the current
- operational status of this uni-directional PVC
- flow. This value affects the PVC status indicated
- across the ingress NNI/UNI of the uni-directional
- PVC flow."
- ::= { frPVCConnectEntry 6 }
-
- frPVCConnectLastChange OBJECT-TYPE
- SYNTAX TimeTicks
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of sysUpTime at the time this uni-
- directional PVC flow entered its current
- operational state. If the current state was
- entered prior to the last re-initialization of the
- proxy-agent, then this object contains a zero
- value."
- ::= { frPVCConnectEntry 7 }
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 29]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- frPVCConnectMaxFrameSize OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The value of this object is the size in octets of
- the largest frame relay information field for this
- uni-directional PVC flow in the ingress direction
- (into the frame relay network). The value of
- frPVCConnectMaxFrameSize must be less than or
- equal to the corresponding ifMtu for this Frame
- Relay UNI/NNI logical port."
- ::= { frPVCConnectEntry 8 }
-
- frPVCConnectBc OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the
- committed burst size (Bc) parameter (measured in
- bits) for this uni-directional PVC flow."
- ::= { frPVCConnectEntry 9 }
-
- frPVCConnectBe OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the excess
- burst size (Be) parameter (measured in bits) for
- this uni-directional PVC flow."
- ::= { frPVCConnectEntry 10 }
-
- frPVCConnectCIR OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the
- committed information rate (CIR) parameter
- (measured in bits per second) for this uni-
- directional PVC flow."
- ::= { frPVCConnectEntry 11 }
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 30]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- frPVCConnectGenericPointer OBJECT-TYPE
- SYNTAX OBJECT IDENTIFIER
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The value of this object is used as a pointer to
- the Generic VC Table. This OID should contain the
- appropriate ifIndex and vcIndex values for the
- Generic VC Table."
- ::= { frPVCConnectEntry 12 }
-
- frPVCConnectStatus OBJECT-TYPE
- SYNTAX RowStatus
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The status of this entry in the
- frPVCConnectTable. This variable is used to
- create new PVC segment flows and to change
- existing PVC segment flows. This capability may
- not be supported for all implementations."
- ::= { frPVCConnectEntry 13 }
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 31]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- -- The PVC End-Point Group
-
- -- This table provides statistics for a PVC segment
- -- End-point.
-
- -- A PVC segment end-point is identified by a UNI/NNI
- -- logical port index value and DLCI index value.
-
-
- frPVCEndptTable OBJECT-TYPE
- SYNTAX SEQUENCE OF FrPVCEndptEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The Frame Relay PVC End-Point table. This Table
- is used to model a PVC end-point. This table
- contains the statistics for a PVC end-point."
- ::= { frnetservObjects 4 }
-
- frPVCEndptEntry OBJECT-TYPE
- SYNTAX FrPVCEndptEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "An entry in the Frame Relay PVC Endpt table."
- INDEX { frPVCEndptIfIndex, frPVCEndptDLCIIndex }
- ::= { frPVCEndptTable 1 }
-
- FrPVCEndptEntry ::=
- SEQUENCE {
- frPVCEndptIfIndex
- Integer32,
- frPVCEndptDLCIIndex
- Integer32,
- frPVCEndptRcvdSigStatus
- INTEGER,
- frPVCEndptInFrames
- Counter32,
- frPVCEndptOutFrames
- Counter32,
- frPVCEndptInDEFrames
- Counter32,
- frPVCEndptInExcessFrames
- Counter32,
- frPVCEndptOutExcessFrames
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 32]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- Counter32,
- frPVCEndptInDiscards
- Counter32,
- frPVCEndptInOctets
- Counter32,
- frPVCEndptOutOctets
- Counter32
- }
-
- frPVCEndptIfIndex OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The value of this object is equal to MIB II's
- ifIndex value for this UNI/NNI logical port."
- ::= { frPVCEndptEntry 1 }
-
- frPVCEndptDLCIIndex OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the DLCI
- value for this PVC segment end-point."
- ::= { frPVCEndptEntry 2 }
-
- frPVCEndptRcvdSigStatus OBJECT-TYPE
- SYNTAX INTEGER {
- deleted(1),
- active(2),
- inactive(3),
- none(4)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object identifies the PVC
- status received via the local in-channel signaling
- procedures for this PVC segment end-point. This
- object is only pertinent for interfaces that
- perform the bidirectional procedures. For user-
- to-network network side procedures, the value of
- this object should be none."
- ::= { frPVCEndptEntry 3 }
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 33]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- frPVCEndptInFrames OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of frames received by the network
- (ingress) for this PVC segment end-point. This
- includes any frames discarded by the network due
- to submitting more than Bc + Be data or due to any
- network congestion recovery procedures."
- ::= { frPVCEndptEntry 4 }
-
- frPVCEndptOutFrames OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of frames sent by the network (egress)
- regardless of whether they are Bc or Be frames for
- this PVC segment end-point."
- ::= { frPVCEndptEntry 5 }
-
- frPVCEndptInDEFrames OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of frames received by the network
- (ingress) with the DE bit set to (1) for this PVC
- segment end-point."
- ::= { frPVCEndptEntry 6 }
-
- frPVCEndptInExcessFrames OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of frames received by the network
- (ingress) for this PVC segment end-point which
- were treated as excess traffic. Frames which are
- sent to the network with DE set to zero are
- treated as excess when more than Bc bits are
- submitted to the network during the Committed
- Information Rate Measurement Interval (Tc).
- Excess traffic may or may not be discarded at the
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 34]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- ingress if more than Bc + Be bits are submitted to
- the network during Tc. Traffic discarded at the
- ingress is not recorded in
- frPVCEndptInExcessFrames. Frames which are sent
- to the network with DE set to one are also treated
- as excess traffic."
- ::= { frPVCEndptEntry 7 }
-
- frPVCEndptOutExcessFrames OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of frames sent by the network (egress)
- for this PVC segment end-point which were treated
- as excess traffic. (The DE bit may be set to
- one.)"
- ::= { frPVCEndptEntry 8 }
-
- frPVCEndptInDiscards OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of frames received by the the network
- (ingress) that were discarded due to traffic
- enforcement for this PVC segment end-point."
- ::= { frPVCEndptEntry 9 }
-
- frPVCEndptInOctets OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of octets received by the network
- (ingress) for this PVC segment end-point. This
- counter should only count octets from the
- beginning of the frame relay header field to the
- end of user data. If the network supporting Frame
- Relay can not count octets, then this count should
- be an approximation."
- ::= { frPVCEndptEntry 10 }
-
- frPVCEndptOutOctets OBJECT-TYPE
- SYNTAX Counter32
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 35]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The number of octets sent by the network (egress)
- for this PVC segment end-point. This counter
- should only count octets from the beginning of the
- frame relay header field to the end of user data.
- If the network supporting Frame Relay can not
- count octets, then this count should be an
- approximation."
- ::= { frPVCEndptEntry 11 }
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 36]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- -- The Frame Relay Accounting Groups
-
- -- The groups are the following:
- -- Accounting on a PVC basis
- -- Accounting on an Interface/Logical Port basis
-
- -- The Accounting on a Frame Relay PVC basis Group
-
- -- The accounting information is collected for a PVC
- -- segment end-point.
-
- frAccountPVCTable OBJECT-TYPE
- SYNTAX SEQUENCE OF FrAccountPVCEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The Frame Relay Accounting PVC table. This Table
- is used to perform accounting on a PVC segment
- end-point basis."
- ::= { frnetservObjects 5 }
-
- frAccountPVCEntry OBJECT-TYPE
- SYNTAX FrAccountPVCEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "An entry in the Frame Relay Accounting PVC
- table."
- INDEX { frAccountPVCIfIndex, frAccountPVCDLCIIndex }
- ::= { frAccountPVCTable 1 }
-
- FrAccountPVCEntry ::=
- SEQUENCE {
- frAccountPVCIfIndex
- Integer32,
- frAccountPVCDLCIIndex
- Integer32,
- frAccountPVCSegmentSize
- Integer32,
- frAccountPVCInSegments
- Counter32,
- frAccountPVCOutSegments
- Counter32
- }
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 37]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- frAccountPVCIfIndex OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The value of this object is equal to MIB II's
- ifIndex value for this UNI/NNI logical port."
- ::= { frAccountPVCEntry 1 }
-
- frAccountPVCDLCIIndex OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the DLCI
- value for this PVC segment end-point."
- ::= { frAccountPVCEntry 2 }
-
- frAccountPVCSegmentSize OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the Segment
- Size for this PVC segment end-point."
- ::= { frAccountPVCEntry 3 }
-
- frAccountPVCInSegments OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the number
- of segments received by this PVC segment end-
- point."
- ::= { frAccountPVCEntry 4 }
-
- frAccountPVCOutSegments OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the number
- of segments sent by this PVC segment end-point."
- ::= { frAccountPVCEntry 5 }
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 38]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- -- The Accounting on a Frame Relay Logical Port basis Group
-
-
- frAccountLportTable OBJECT-TYPE
- SYNTAX SEQUENCE OF FrAccountLportEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The Frame Relay Accounting Logical Port table.
- This Table is used to perform accounting on a
- UNI/NNI Logical Port basis."
- ::= { frnetservObjects 6 }
-
- frAccountLportEntry OBJECT-TYPE
- SYNTAX FrAccountLportEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "An entry in the Frame Relay Accounting Logical
- Port table."
- INDEX { frAccountLportIfIndex }
- ::= { frAccountLportTable 1 }
-
- FrAccountLportEntry ::=
- SEQUENCE {
- frAccountLportIfIndex
- Integer32,
- frAccountLportSegmentSize
- Integer32,
- frAccountLportInSegments
- Counter32,
- frAccountLportOutSegments
- Counter32
- }
-
- frAccountLportIfIndex OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The value of this object is equal to MIB II's
- ifIndex value for this UNI/NNI logical port."
- ::= { frAccountLportEntry 1 }
-
- frAccountLportSegmentSize OBJECT-TYPE
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 39]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- SYNTAX Integer32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the Segment
- Size for this UNI/NNI logical port."
- ::= { frAccountLportEntry 2 }
-
- frAccountLportInSegments OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the number
- of segments received by this UNI/NNI logical
- port."
- ::= { frAccountLportEntry 3 }
-
- frAccountLportOutSegments OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object is equal to the number
- of segments sent by this UNI/NNI logical port."
- ::= { frAccountLportEntry 4 }
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 40]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- -- Frame Relay Network Service TRAPS
-
- frPVCConnectStatusChange NOTIFICATION-TYPE
- OBJECTS { frPVCConnectIngressIfIndex, frPVCConnectIngressDLCIIndex,
- frPVCConnectEgressIfIndex, frPVCConnectEgressDLCIIndex,
- frPVCConnectOperStatus, frPVCEndptRcvdSigStatus }
- STATUS current
- DESCRIPTION
- "This trap indicates that the indicated PVC has
- changed state. This trap is not sent if an FR-UNI
- changes state; a linkDown or linkUp trap should be
- sent instead."
- ::= { frnetservTraps 1 }
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 41]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- -- Conformance Information
-
- frnetservConformance OBJECT IDENTIFIER ::= { frnetservMIB 3 }
-
- frnetservGroups OBJECT IDENTIFIER ::= { frnetservConformance 1 }
- frnetservCompliances OBJECT IDENTIFIER ::= { frnetservConformance 2 }
-
- -- Compliance Statements
-
- frnetservCompliance MODULE-COMPLIANCE
- STATUS current
- DESCRIPTION
- "The compliance statement for SNMPv2 entities
- which have Frame Relay Network Service Interfaces."
-
- MODULE -- this module
- MANDATORY-GROUPS { frnetservLportGroup,
- frnetservMgtVCSigGroup,
- frnetservPVCConnectGroup,
- frnetservPVCEndptGroup }
-
- GROUP frnetservAccountPVCGroup
- DESCRIPTION
- "This group is optional for Frame Relay interfaces.
- It is
- mandatory if and only if accounting is performed
- on a PVC
- basis this
- Frame Relay interface."
-
- GROUP frnetservAccountLportGroup
- DESCRIPTION
- "This group is optional for Frame Relay interfaces.
- It is
- mandatory if and only if accounting is
- performed on a
- logical port basis this
- Frame Relay interface."
-
- OBJECT frPVCConnectAdminStatus
- SYNTAX INTEGER {
- deleted(1),
- active(2),
- inactive(3),
- testing(4)
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 42]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- }
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT frPVCConnectMaxFrameSize
- SYNTAX Integer32
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT frPVCConnectBc
- SYNTAX Integer32
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT frPVCConnectBe
- SYNTAX Integer32
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT frPVCConnectCIR
- SYNTAX Integer32
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT frPVCConnectGenericPointer
- SYNTAX OBJECT IDENTIFIER
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT frPVCConnectStatus
- SYNTAX INTEGER { active(1) } -- subset of RowStatus
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required, and only one of the
- six enumerated values for the RowStatus textual
- convention need be supported, specifically:
- active(1)."
- ::= { frnetservCompliances 1 }
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 43]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- -- Units of Conformance
-
- frnetservLportGroup OBJECT-GROUP
- OBJECTS { frLportNumPlan, frLportContact, frLportLocation,
- frLportType,
- frLportAddrDLCILen, frLportVCSigProtocol,
- frLportVCSigPointer }
- STATUS current
- DESCRIPTION
- "A collection of objects providing information applicable
- to a Frame Relay Logical Port."
- ::= { frnetservGroups 1 }
-
- frnetservMgtVCSigGroup OBJECT-GROUP
- OBJECTS { frMgtVCSigProced,
- frMgtVCSigUserN391,
- frMgtVCSigUserN392,
- frMgtVCSigUserN393,
- frMgtVCSigUserT391,
- frMgtVCSigNetN392,
- frMgtVCSigNetN393,
- frMgtVCSigNetT392,
- frMgtVCSigNetnN4,
- frMgtVCSigNetnT3,
- frMgtVCSigUserLinkRelErrors,
- frMgtVCSigUserProtErrors,
- frMgtVCSigUserChanInactive,
- frMgtVCSigNetLinkRelErrors,
- frMgtVCSigNetProtErrors,
- frMgtVCSigNetChanInactive }
- STATUS current
- DESCRIPTION
- "A collection of objects providing information
- applicable to the
- Local In-Channel Signaling Procedures used for a
- UNI/NNI logical port."
- ::= { frnetservGroups 2 }
-
- frnetservPVCConnectGroup OBJECT-GROUP
- OBJECTS { frPVCConnectAdminStatus, frPVCConnectOperStatus,
- frPVCConnectLastChange,
- frPVCConnectMaxFrameSize, frPVCConnectBc,
- frPVCConnectBe,
- frPVCConnectCIR,
- frPVCConnectGenericPointer, frPVCConnectStatus }
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 44]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- STATUS current
- DESCRIPTION
- "A collection of objects providing information applicable
- to a Frame Relay PVC connection."
- ::= { frnetservGroups 3 }
-
- frnetservPVCEndptGroup OBJECT-GROUP
- OBJECTS { frPVCEndptRcvdSigStatus, frPVCEndptInFrames,
- frPVCEndptOutFrames, frPVCEndptInDEFrames,
- frPVCEndptInExcessFrames, frPVCEndptOutExcessFrames,
- frPVCEndptInDiscards,
- frPVCEndptInOctets, frPVCEndptOutOctets }
- STATUS current
- DESCRIPTION
- "A collection of objects providing information application
- to a Frame Relay PVC end-point."
- ::= { frnetservGroups 4 }
-
- frnetservAccountPVCGroup OBJECT-GROUP
- OBJECTS { frAccountPVCSegmentSize, frAccountPVCInSegments,
- frAccountPVCOutSegments }
- STATUS current
- DESCRIPTION
- "A collection of objects providing accounting
- information application
- to a Frame Relay PVC end-point."
- ::= { frnetservGroups 5 }
-
- frnetservAccountLportGroup OBJECT-GROUP
- OBJECTS { frAccountLportSegmentSize, frAccountLportInSegments,
- frAccountLportOutSegments }
- STATUS current
- DESCRIPTION
- "A collection of objects providing accounting
- information application
- to a Frame Relay logical port."
- ::= { frnetservGroups 6 }
-
-
- END
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 45]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- 9. Acknowledgments
-
- This document was produced jointly by the Frame Relay Forum
- Technical Committee MIB Working Group and the Frame Relay
- Service MIB Working Group.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 46]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- 10. References
-
- [1] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,
- "Structure of Management Information for version 2 of the
- Simple Network Management Protocol (SNMPv2)", RFC 1442, SNMP
- Research, Inc., Hughes LAN Systems, Dover Beach Consulting,
- Inc., Carnegie Mellon University, April 1993.
-
- [2] Galvin, J., and K. McCloghrie, "Administrative Model for
- version 2 of the Simple Network Management Protocol
- (SNMPv2)", RFC 1445, Trusted Information Systems, Hughes LAN
- Systems, April 1993.
-
- [3] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,
- "Protocol Operations for version 2 of the Simple Network
- Management Protocol (SNMPv2)", RFC 1448, SNMP Research, Inc.,
- Hughes LAN Systems, Dover Beach Consulting, Inc., Carnegie
- Mellon University, April 1993.
-
- [4] McCloghrie, K., and M. Rose, "Management Information Base for
- Network Management of TCP/IP-based internets - MIB-II", RFC
- 1213, Hughes LAN Systems, Performance Systems International,
- March 1991.
-
- [5] K. McCloghrie and F. Kastenholz, Evolution of Interfaces
- Group of MIB-II, Internet Draft, September 20, 1993.
-
- [6] K. R. Rodemann, Service Management Architecture
- for Virtual Connection Services,
- Internet-Draft, July 1993.
-
- [7] ANSI T1.617-1991, American National Standard
- for Telecommunications - Integrated
- Services Digital Network (ISDN) -
- Digital Subscriber Signaling System No. 1 (DSS1) -
- Signaling Specification for Frame Relay Bearer Service.
-
- [8] Management Information Base for Frame Relay DTEs,
- RFC 1315, C. Brown,
- F. Baker, and C. Carvalho (editors),
- Internet Engineering Task Force, Network
- Information Center, SRI International, Menlo Park, CA,
- April 1992.
-
- [9] Multi-Protocol Interconnect over Frame Relay, RFC 1490,
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 47]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- Obsoletes RFC 1294,
- T. Bradley, C. Brown, A. Malis,
- Network Information Center, SRI International,
- Menlo Park, CA, July 1993.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 48]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- 11. Security Considerations
-
- Security issues are not discussed in this memo.
-
-
- 12. Authors' Addresses
-
- Tracy A. Brown
- Bell Communications Research
- 331 Newman Springs Road
- P.O. Box 7020
- Red Bank, NJ 07701-7020
-
- Phone: (908) 758-2107
-
- EMail: tacox@mail.bellcore.com
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 49]
-
-
-
-
-
- Internet Draft Frame Relay Service MIB October 14, 1993
-
-
- Table of Contents
-
-
- 1 Status of this Memo ................................... 1
- 2 Abstract .............................................. 1
- 3 The SNMPv2 Network Management Framework ............... 2
- 4 Object Definitions .................................... 3
- 5 Overview .............................................. 4
- 5.1 Scope of MIB ........................................ 4
- 5.2 Frame Relay Service MIB Terminology ................. 7
- 5.3 Apply MIB II to a Frame Relay Service ............... 9
- 6 Object Definitions .................................... 14
- 6.1 The Frame Relay Service Logical Port Group .......... 15
- 6.2 The Frame Relay Management VC Signaling Group ....... 19
- 6.3 Frame Relay PVC Connection Group .................... 26
- 6.4 The PVC End-Point Group ............................. 32
- 6.5 Frame Relay Accounting Groups ....................... 37
- 7 Frame Relay Network Service TRAPS ..................... 41
- 8 Conformance Information ............................... 42
- 9 Acknowledgments ....................................... 46
- 10 References ........................................... 47
- 11 Security Considerations .............................. 49
- 12 Authors' Addresses ................................... 49
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- T. Brown (editor) Expires 5/14/94 [Page 50]
-
-